Renewable Generation with Storage & Grid Flexibility
Renewable generation coupled with storage or flexibility measures; credits follow the additional grid absorption and displaced marginal generation, not installed capacity.
About this methodology
The Renewable Generation with Storage & Grid Flexibility profile (RE-STORAGE) is a Renewable Energy methodology profile used by the Athlas Verity engine to estimate and independently verify carbon outcomes for renewable plus storage, battery energy storage integration, grid flexibility programme. Renewable generation coupled with storage or flexibility measures; credits follow the additional grid absorption and displaced marginal generation, not installed capacity.
Athlas classifies this profile at Tier 2 — standard with medium confidence. Estimates are derived from directly observable satellite signals, and a conservative uncertainty deduction of 15% is applied to net creditable volume. The profile sets parameterisation, dataset bundles and evidence requirements; the core accounting chain is shared across the platform.
Verification is evidence-led. A project mapped to this profile must supply 3 mandatory evidence items plus 2 optional supporting records. Athlas cross-checks the submitted project boundary and documents against 3 Earth-observation and ancillary data layers, then issues a tamper-evident verification report that can be reviewed independently.
How Athlas verifies this
- 1
1. Boundary & evidence intake
The project boundary (GeoJSON) is ingested and validated against the 5 evidence requirements defined for profile RE-STORAGE. Ownership, legality and truthfulness declarations are recorded for the audit trail.
- 2
2. Baseline reconstruction
Reference conditions are reconstructed from a multi-year satellite time series to establish a defensible counterfactual for renewable plus storage.
- 3
3. Satellite measurement
The primary signal is measured from NOAA/VIIRS/DNB/MONTHLY_V1/VCMSLCFG (bands avg_rad) with a mean reducer at 500 m, combined with the remaining 2 supporting layers for terrain, moisture, climate and land-cover context.
- 4
4. Conservative accounting
Results are passed through the shared accounting chain using the profile's own parameters, then reduced by the profile uncertainty deduction of 15% to give a conservative, uncertainty-aware creditable volume.
- 5
5. Report & on-chain anchoring
A verification report is generated with a tamper-evident hash and anchored immutably, so the Renewable Energy result for RE-STORAGE can be independently reviewed and its retirement tracked.
Satellite & Earth-observation layers
| Role | Dataset | Bands | Reducer | Scale |
|---|---|---|---|---|
| electrification proxy | NOAA/VIIRS/DNB/MONTHLY_V1/VCMSLCFG | avg_rad | mean | 500 m |
| site land cover | ESA/WorldCover/v200 | Map | mode | 10 m |
| thermal context(optional) | MODIS/061/MOD11A2 | LST_Day_1km | median | 1000 m |
Profile parameters & provenance
A calibrated default is not a standard value. Before a claim under this profile is marked verified, every calibrated default it relies on must be replaced or justified with project-specific measurement.
Round-trip efficiency of the storage system, applied to energy shifted rather than generated.
Nameplate storage capacity, used to bound the energy that can be shifted.
Increase in sink strength under the improved practice relative to the baseline.
Build-margin or combined-margin emission factor for grid-connected generation. Defaults are indicative and must be replaced by the published margin for the crediting period.
Crediting lifetime assumed for the plant. A methodological convention, not a physical property.
The value comes from the cited standard. A reviewer can open the document and check the number.
A defensible default drawn from the literature, not a standard value. It must be replaced or justified with project-specific measurement before the claim is verified.
A deliberate Athlas choice — a buffer, deduction or weighting. Not a scientific constant and never presented as one.
Required evidence
Metering / generation records
Required · accepts csv, pdf, xlsx
Grid connection / power offtake agreement
Required · accepts pdf
Operations & maintenance log
Optional · accepts pdf, csv
Data truthfulness declaration
Required · accepts pdf, jpg, png
Project field photos (multi)
Optional · accepts jpg, png, webp
Verification workflow
Frequently asked questions
What is the Renewable Generation with Storage & Grid Flexibility (RE-STORAGE) methodology profile?
It is a Renewable Energy methodology profile in the Athlas Verity library. Renewable generation coupled with storage or flexibility measures; credits follow the additional grid absorption and displaced marginal generation, not installed capacity. It applies to renewable plus storage, battery energy storage integration, grid flexibility programme and sets the parameters, satellite dataset bundle and evidence requirements used to verify a project mapped to it.
What evidence is required for profile RE-STORAGE?
Mandatory evidence includes: Metering / generation records; Grid connection / power offtake agreement; Data truthfulness declaration. Optional supporting records such as Operations & maintenance log; Project field photos (multi) strengthen the assessment.
How does Athlas verify a RE-STORAGE project with satellites?
Athlas measures the project using 3 Earth-observation layers, including NOAA/VIIRS/DNB/MONTHLY_V1/VCMSLCFG (avg_rad). Estimates are conservative: a 15% deduction is applied to net credits.
Which verification domain does RE-STORAGE belong to?
Profile RE-STORAGE belongs to the Renewable Energy domain. Projects are routed through the corresponding verification workflow and dashboard at the Renewable Energy verification area.
Related methodology profiles
Grid-Connected Renewable Generation — Large Scale (Combined-Margin Baseline)
Grid-Connected Renewable Generation — Small Scale
Solar Photovoltaic Generation
Wind Power Generation
Run-of-River & Small Hydropower
Biomass & Biogas Energy Generation